CFGNAV: Configure Positioning Frequency

Applicable to: UC6580, UM620 series1, UM621 series, UM670A, UM680A, UM681A

Read Positioning Frequency Configuration

Syntax $CFGNAV
Example $CFGNAV
Description Read the positioning frequency configuration.
The receiver outputs CFGNAV message after receiving this command.
Input/Output Input
No parameters  

1. Not supported by UM620S.

Set/Output Positioning Frequency Configuration

Syntax $CFGNAV,MeasRate,NavRate,DRNavRate
Example $CFGNAV,1000,1000,100
Description Set or output positioning frequency configuration
Input/Output Input/output
Parameter Definition
Parameter Format Description
MeasRate UINT Observation interval; unit: ms;
1000 - corresponding to 1 Hz observation frequency
200 - corresponding to 5 Hz observation frequency
100 - corresponding to 10 Hz observation frequency
NavRate UINT GNSS positioning interval; unit: ms;
1000 - corresponding to 1 Hz GNSS positioning frequency
200 - corresponding to 5 Hz GNSS positioning frequency
100 - corresponding to 10 Hz GNSS positioning frequency
DRNavRate UINT INS positioning interval; unit: ms;
100 - corresponding to 10 Hz INS positioning frequency
50 - corresponding to 20 Hz INS positioning frequency
20 - corresponding to 50 Hz INS positioning frequency
Except for the integrated products, the parameter is invalid for other modules
which return 0 when making an inquiry.

MeasRate and NavRate should be the same, otherwise, the message would return FAIL.

When the GNSS positioning frequency is 10 Hz, CFGINS cannot be configured to 2 - Vehicle-mounted mode to enable the second NMEA output.

After the configuration of NavRate is finished, GSV and the RTCM Ephemeris will be reset to output at 1 Hz, and the Ionosphere Information and TGD/ISC Information in extended RTCM messages will output once every 30 s.

After the configuration of DRNavRate is finished, SNRSTAT will output at 1 Hz.

 